AC never shuts off

vein5

Active Member
Well I bought a 1100btu dual hose ac for my 5x10x8 room with 2 600's. I am stumped on how i should exhaust the air. My exhaust is a 800cfm blower that goes into a return duct my my central air. Should my blower be set on high or low while the ac is running. I notices the ac never shut off yesterday.
 
Was the temp where the unit was down as low as you had the thermostat?
I would keep your exhaust on high while it's on so you're sure you have adequate flow and are not fighting yourself.
 
1100 or 11000 btu's? Exhausting into your duct work will result in your whole house smelling dank. If it is a tent in a room and that unit is actually 11000 btu's then cool the room the tent is in and draw the cool air into the tent. I would exhaust up your chimney or somewhere else using at least a carbon filter.
 
1100 or 11000 btu's? Exhausting into your duct work will result in your whole house smelling dank. If it is a tent in a room and that unit is actually 11000 btu's then cool the room the tent is in and draw the cool air into the tent. I would exhaust up your chimney or somewhere else using at least a carbon filter.


Ok Listen this is very bad NEVER EXHAUST IN TO A CHIMNEY UNLESS YOU KNOW WHAT THE FUCK YOU ARE DOING, DO YOU KNOW IF NOT PROPERLY DONE YOU CAN KILL YES KILL EVERYONE IN THAT HOUSE.

THIS BY TRADE NAME IS CALLED INDUCING :

CERTAIN HIGHER EFFICENCY APPLIANCES HAVE WHAT IS CALL A INDUCER MOTOR ON THE EXHAUST OF THAT APPLIENCE
IN THE APP WHEN INDUCING EXHASUT IN A CHIMNEY IT MUST BE WHAT IS CALLED LINED

THIS IS DONE BY STREATCHING A CERTAIN DIA. STANLESSSTEEL LINER DOWN A EXSITING CHIMNEY

WHY BECAUSE YOU ARE INDUCING PRESSURE IN THE CHIMNEY

A STANDARD CHIMNEY MADE OF BRICK AND MOTOUR WILL LEAK AND ALSO WHEN INDUCED IT WILL PRODUCE A FAIR AMOUNT OF CONDENSATE AND A RAPID DECAY OF THE BRICK AND MOTUR WILL HAPPEN AT A FASTER RATE = MORE LEAKAGE

SO IF THIS PERSON HAS A GAS APPLIANCE (WATER HEATER) FURNANCE,BOILER ECT ECT: THE CARBON MONOXCIDE WILL ENTER THE HOME AND NOT BE PROPERLY TRANSMITTED OUT THE CHIMNEY.

i CAN GO ON AND ON WITH THE PROPER WAY TO DUE THIS ,BUT THEY ARE MANY OTHER FACTORS THAT HAVE TO BE CONSIDERD WHEN DUING THIS:

WHEN THIS IS DONE iNDUCING AIR IN TO A CHIMNEY EVERY SINGLE DWELLING WILL REQUIRE ITS OWN PLAN OF ACTION FOR THAT SPECFIC APPLICATION.

PLEASE DO NOT TRY THIS UNLESS YOU REALLY UNDERSTAND THIS CONCEPT IT IS NO JOKE A LIFE AND DEATH MATTER.
 
Ok Listen this is very bad NEVER EXHAUST IN TO A CHIMNEY UNLESS YOU KNOW WHAT THE FUCK YOU ARE DOING, DO YOU KNOW IF NOT PROPERLY DONE YOU CAN KILL YES KILL EVERYONE IN THAT HOUSE.

THIS BY TRADE NAME IS CALLED INDUCING :

CERTAIN HIGHER EFFICENCY APPLIANCES HAVE WHAT IS CALL A INDUCER MOTOR ON THE EXHAUST OF THAT APPLIENCE
IN THE APP WHEN INDUCING EXHASUT IN A CHIMNEY IT MUST BE WHAT IS CALLED LINED

THIS IS DONE BY STREATCHING A CERTAIN DIA. STANLESSSTEEL LINER DOWN A EXSITING CHIMNEY

WHY BECAUSE YOU ARE INDUCING PRESSURE IN THE CHIMNEY

A STANDARD CHIMNEY MADE OF BRICK AND MOTOUR WILL LEAK AND ALSO WHEN INDUCED IT WILL PRODUCE A FAIR AMOUNT OF CONDENSATE AND A RAPID DECAY OF THE BRICK AND MOTUR WILL HAPPEN AT A FASTER RATE = MORE LEAKAGE

SO IF THIS PERSON HAS A GAS APPLIANCE (WATER HEATER) FURNANCE,BOILER ECT ECT: THE CARBON MONOXCIDE WILL ENTER THE HOME AND NOT BE PROPERLY TRANSMITTED OUT THE CHIMNEY.

i CAN GO ON AND ON WITH THE PROPER WAY TO DUE THIS ,BUT THEY ARE MANY OTHER FACTORS THAT HAVE TO BE CONSIDERD WHEN DUING THIS:

WHEN THIS IS DONE iNDUCING AIR IN TO A CHIMNEY EVERY SINGLE DWELLING WILL REQUIRE ITS OWN PLAN OF ACTION FOR THAT SPECFIC APPLICATION.

PLEASE DO NOT TRY THIS UNLESS YOU REALLY UNDERSTAND THIS CONCEPT IT IS NO JOKE A LIFE AND DEATH MATTER.
This guy is FAMOUS for doing things wrong. Everything he suggests is always backwards of everyone else. It's amazing he can even grow,let alone call himself SIR GANJA, What a joke.
 
YES was just telling someone here in RIU to look in to a Mixingbox with makeup air design for those extra hot day your system has trouble handling the temps , Good find Chuck
 
If u are exhausting hot air into your hvac system not only will your ac never shut off but u are also jeopardizing the life of your compressor. Do not exhaust hot air into your R/A,unless its in the heating cycle. Run your exhaust outside
 
OK sorry for the confusion, the exhaust for the whole grow room goes into my central air return with a 10 in scrubber. The out and intake from the air conditioner come from the outside like a window unit so the hot air from the air condition go out the window. I guess what I'm asking should the whole room exhaust be on low or high. If its on high won't it just suck the cold air out of the room. How do you guys do it
 
OK sorry for the confusion, the exhaust for the whole grow room goes into my central air return with a 10 in scrubber. The out and intake from the air conditioner come from the outside like a window unit so the hot air from the air condition go out the window. I guess what I'm asking should the whole room exhaust be on low or high. If its on high won't it just suck the cold air out of the room. How do you guys do it
do you have a intake for the room?
 
op needs to put up a picture or something, I'm having a hard time deciding why you'd exhaust at all since you just paid to cool the air you're exhausting.
 
unless you supplement there should be plenty without exhausting , if your room is that air tight you should be supplementing in the first place.
 
I'm pretty stoned and just reread that, not sure it's as understandable as I meant it to be , oops.
I dunno wtf I meant by "unless you supplement there should be plenty". maybe you can figure it out.
 
I have a co2 tank but I don't think its worth the Hassel BC I have to drive 40min to fill. I would need to fork out another $1200 for controls and burner.
 